nagios监控xenserver温度

 cat check_xen_temp.sh
#!/bin/bash


ipmitool sensor | gawk -F'|' '
BEGIN { 
	EXIT=0;
	MSG[0]="OK: ";
	MSG[1]="WARNING: ";
	MSG[2]="CRITICAL: ";
	perf="";
}

{ gsub(/\t/," "); gsub(/ +/," "); gsub(/ +\|/,"|"); gsub(/\| +/,"|") }

/^[^|]+\|0x0\|/ { next; };

/^[^|]+\|na\|/ { next; };

/degrees C/ {
	THING=$1;
	TEMP=$2;
	OK=$4;
	WARN=$8;
        CRIT=$9;
	if (OK ~ /ok/) {
	    MSG[0] = sprintf("%s %s is %dC,",MSG[0] ,THING,TEMP);
	    perf = sprintf("%s %s=%d;%d;%d;0;100;",perf,THING,TEMP,WARN,CRIT);
	    next;
	}
	if (CRIT !~ /na/ && TEMP>=CRIT) {
	    MSG[2] = sprintf("%s %s is %dC (max %d) ", 
		MSG[2], THING, TEMP, CRIT);
	    perf = sprintf("%s %s=%d;%d;%d;0;100;",perf,THING,TEMP,WARN,CRIT);
	    EXIT=2;
	    next;
	}

	if (WARN !~ /na/ && TEMP>=WARN) {
            MSG[1] = sprintf("%s %s is %dC (max %dC, critical at %dC) ",
		MSG[1], THING, TEMP, CRIT);
	    perf = sprintf("%s %s=%d;%d;%d;0;100;",perf,THING,TEMP,WARN,CRIT);
	    if (EXIT=0) EXIT=1;
	    next;
	}
	
	MSG[2] = sprintf("%s %s is %d (%s) ", MSG[2], THING, TEMP, OK);
	perf = sprintf("%s %s=%d;%d;%d;0;100;",perf,THING,TEMP,WARN,CRIT);
	if (EXIT=0) EXIT=1;
}

END {
    gsub(/, *$/,"",MSG[EXIT]);
    gsub(/ Temp/,"",MSG[EXIT]);
    gsub(/ Temp/,"",perf);
    print MSG[EXIT],"|",perf;
    exit EXIT;
}
'